Shenyang Yushi Xianfeng Inspection Instrument Co., Ltd.
|
Payment Terms: | T/T,L/C,D/A,D/P,WU,Paypal,Money Gram |
Place of Origin: | Liaoning, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
YUSHI YUT28 Series Ultrasonic Flaw Detector (YUT2820)
· Same features as YUT2600, Plus AVG Curve, Φ Value Calculation, Distance Compensation
· Variable square wave pulse generator,four settings of adjustable impedance matching,two settings of adjustable echo signal filter and multi-speed adjustable repetition frequency
· Echo to Echo: No need of zero calibration, the net thickness of the base material can be directly measured through the coating
· Bulk Storage: Up to 1000 data sets can be stored, including waveforms, curves and parameters, etc.
· Rugged & Durable housing: designed for harsh environment
Product Description
Style:YUT2820
Φ Value Calculation: This function is used for calculating the flaw quivalent
Measuring Point: Peak Mode or Front Mode
Wave Crest Memory: Real time envelopes show the highest wave of the flaws and record the maximum value of the flaws, it is helpful to exact positioning and fast
Automatic Gain: Automatically adjust the gain to the preset amplitude height
Alarming Function: Afferent echo/echo loss alarming
Solid Waveform: The solid waveform can enhancing the waveform visual contrast so the omission will hardly happen during the fast testing
Real-time Clock: Automatically record the date and time of the stored waveforms
Display Freezing: Catching the waveform and sound path data at any moment
Flaw Positioning: Real-time displaying the sound path S, horizontal height X, depth Y, and wave height
Digital Inhibition: 0-80%, increasing by 1%, not affecting the linearity and gain
Independent Measurement: two independent measurement gates, monitoring the echo amplitude and the sound path distance
DAC/AVG Curve Functions: Perfect DAC curve functions enable the curves to change along with the changes of the gain, sound path, and displacement
Transverse Wave Testing Method: When using transverse wave to detect flaws, the depths of the second and third waves are automatically calculated according to the slab
Pulse Generator with Changeable Width and Scope: The voltage of the pulse generator can be changed between 50V to 400V continuously, The width of the pulse can be change d between 25ns to 1000ns continuously
Damping: Changed among 4 levels: 33/50/100/500Ω
Wave Signal Filter: Changed between 2 levels: 1-4MHz/0.5-15MHz
Repeating Frequency: Changed freely to avoid unreal signal
Languages: Chinese and English